XHZG-400GF Weichai Gas Series-60HZ
Gas generator set

XHZG-400GF Weichai Gas Series-60HZ

The model of the unit XHZW-400GF
Rated Power 400KW/500KVA
Standby power N/A
Rated voltage 480 V
Rated current 720A
Frequency/Speed 60Hz/1800RPM
Phase / Power factor 3P / PF0.8
Gas Consumption /

    Engine specification

    Engine

    WEICHAI

    Model

    6M33D480E311NG

    Rated power(CH4≥90%)

    480KW

    Standby power

    N/A

    Gas Consumption

    /

    No. of Cylinders

    L-TYPE-6

    Type

    4 cycle

    Aspiration

    Turbocharged, air-to-air cooler

    Frequency/Speed

    60Hz/1800RPM

    Bore*Stroke:

    150*185MM

    Displacement

    19.6L

    Compression Ratio

    11:1

    Turbocharger intake pressure

    /

    Turbocharger outlet temperature

    /

    Exhaust Temperature (after turbine)

    433℃

    Gas System

    Mix type

    Premixing before turbocharger

    Closed-loop lean combustion

    Gas type

    Natural gas

    Intake System

    Air filter with dirty filter core

    ≤50kPa

    Standard clean filter

    ≤30kPa

    Cooling system

    115L

    Lubricating System

    62L

    Electrical system

    Starter motor rated voltage

    DC24V

    Battery charging alternator

    DC28V/35A

    Alternator specification

    Brand

    Leroy-somer

    Place of production

    UK

    Model

    TAL-A473-F

    Type

    brushless

    The connecting way of the phase

    three phase four lines

    Frequency/Speed

    60Hz/1800RPM

    Insulation degree

    H degree

    Grading Protection

    IP23

    Winding connection

    Star

    Voltage regulator type

    AVR

    Bearing

    Single Bearing

    Coating

    Vacuum impregnation

    Coupling

    Flexible disc

    Control system introduction

    Brand

    DEIF

    Place of production

    China

    Model

    AGC150

    The AGC 150 Genset controller containing all necessary functions for control and protection of a genset. The slim design makes the genset controller suitable for paralleling even small gensets thus the AGC 150 is integrable in nearly all types of gensets.

    AGC 150 can be connected in a complete power management system with up to 32 controllers for synchronizing projects, island or parallel to the mains.

    AGC 150 Advanced genset controller, integrating digital, intelligent and network techniques, is used for automatic control and monitoring system of genset. It can carry out functions of automatic start/stop, data measurement, alarm protection and “three remote” (remote control, remote measurement and remote communication). It contains all necessary 3-phase measuring circuits, and all values and alarms are presented on the sun proof LCD display. The LCD display is optional language interface including Chinese, English, Spanish, Russian, Portuguese, Turkish, Polish and French with easy and reliable operation.

    AGC 150 is a compact all-in-one unit designed for the following applications: Island mode / Automatic Mains Failure / Fixed Power/ Peak shaving / Load take-over / Mains power export.

    engine

    Mains

    Generator

    Line voltage (Uab, Ubc, and Uca)

    Line voltage (Uab, Ubc, and Uca)

    Phase voltage (Ua, Ub, and Uc)

    Phase voltage (Ua, Ub, and Uc)

    Frequency HZ

    Frequency HZ

    Voltage regulator type

    AVR

    Load

    Current IA, IB, IC

    Active power KW

    Reactive power KVar

    Apparent power KVA

    Power factor PF

    Generator accumulated energy kWh

    Mains have functions of over/under voltage and lack of phase; Gens have functions

    of over/under voltage, over/under frequency and over current;

    Precision measure and display of parameters about engine

    Dimensions and weights(1 set)

    Type

    Open

    Length(mm)

    3500

    Width(mm)

    1720

    Height(mm)

    1520

    weights(kg)

    detail
    Cummins series Diesel Generator
    XHZ-Series Gas Generator Set1

    Standard Features

    This natural gas engine is characterized by compact structure, reliable operation, excellent technical performances in reliability, power, economical efficiency and exhaust emission, quick start-up, easy operation and least maintenance, etc. It has already become a new power source of power generation equipment and is frequently used as a main or standby power source in coal mine, oil field, farm, gas station and other places. In addition, it can be fueled by natural gas, methane and biomass gas, etc.


    Other Features

    Optional ATS (Automatic Transfer Switch) automatically Switch between the diesel generator and mains in the case of a power failure.

    Auto Synchronization System enables multiple diesel generator sets to be synchronized and connected in parallel.

    XHZ-Series Gas Generator Set1

    Optional Alternator Brands

    • 01

      STAMFORD industrial alternators meet the requirements of the relevant parts of the IEC 60034 and the relevant sections of other international standards such as BS5000-3, ISO 8528-3, VDE 0530, NEMA MG1-32, CSA C22.2-100 and AS 60034. Other standards and certifications can be considered on request.

    • 02

      Leroy-Somer alternator has also obtained products specially designed for application in special fields or environmentsCertification from international organizations such as LCIE, DNV, INERIS, EFECTIS, UL, BSRIA, TUV, CCC, GOST., ensures the quality of our products.All technical performance meets the certification standards and requirements.

    • 03

      The Marathon® brand encompasses a variaty of products and solutions, including single phase and three phase AC motors, NEMA and IEC motors, low and medium voltage motors and Generators.

    • 04

      The XHZ series generators comply with GB755, BS5000 Part III,VDE0530, NEMA MG1-32, IEC34-1, CSA C22.2-100, and AS1359.

    SGC 420 CONTROLLER

    The SGC 420 controller has an advanced battery charge management capability and is specially designed for AMF applications with a mechanical and electronically controlled engine 

    Standard Features

    ● Support automatic, manual and remote start/stop modes;
    ● Can supervise engine safety, electrical load, site battery backup voltage and shelter temperature to cut down on fuel consumption.
    ● The real time clock precisely logs up to 100 events and conducts data analysis.
    ● Auto exercise mode (2 events) allows to start and stop the generator set for for a preconfigured time.
    ● Built-in electronic speed governor is adopted for variable-speed monitoring.
    ● Able to monitor voltage, frequency, load current and power factor of the generator set.
    ● Provided with digital outputs of start relay, fuel relay, alarm horn and more.
    ● Counters for engine starts, engine trips, engine running hours, generator set kWh, kVAh, kVArh and Mains kWh, kVAh, kVArh.

    Optional control system brands

    DEEPSEA、COMAP、HGM.... 

    HOT PRODUCT

    Efficiency That Powers Success: Minimize Downtime and Maximize Productivity with Our High-Performance Generators, Engineered for Your Business

    Make an free consultant

    Your Name*

    Phone Number

    Country

    Company

    Remarks*

    reset